VRF automation and central AC control

Bring your existing VRF and AC systems onto one screen; manage operating hours, setpoint limits and after-hours shutdown centrally on compatible equipment.

Connection
VRF bus, infrared, Modbus, BACnet
Screen
FiotX web and mobile app
Starting point
One floor or 5–10 compatible units
Modern office with glass partitions
What you can do

What can be managed?

In a multi-branch business, an office or a school, knowing when the ACs run is the first step of saving. Then come the rules.

Operating schedules

Working hours per floor, zone or unit group. Public holidays and special days defined separately.

Setpoint limits

The lowest and highest setpoints users can select. Comfort is protected, extreme settings are blocked.

After-hours shutdown

See units left running at close; shut them down by rule or notify the responsible person.

Bulk commands

One command to many units. Devices that don't support a command are shown separately in the preview and skipped.

Status & fault codes

Operating state, mode, setpoint and fault codes in one list. Alarms reach the right person and are tracked to closure.

Energy visibility

Consumption via PN Energy or a compatible meter, split into in-hours and after-hours.

Connectivity

How does each equipment type connect?

Devices are chosen for the equipment on site. Readable and controllable points vary by brand, series and model, and are confirmed in writing at the survey.

EquipmentConnectionSeen & managed
VRF systemPN Climate HVAC gatewayPer-indoor-unit setpoint, mode, fan, status and fault code; setpoint, mode and lock commands on compatible series.
Split & cassette ACPN Climate IR (infrared)On/off, mode and setpoint commands. The AC gives no feedback, so the screen shows "command sent".
Fan coils & AHUsPN Climate HVAC, PN ConnectRun and fault status, filter alarms, control at suitable points.
Pumps, boilers, chillersPN Connect (dry contact, 4–20 mA, 0–10 V, relay)Run and fault contacts, analogue readings, relay control.
Panels & circuitsPN Energy or compatible meterCircuit-level consumption, in-hours vs after-hours.
AmbientPN Sense (battery wireless)Room temperature and humidity where cabling is impractical.
Existing BMSModbus, BACnetData is exposed to the BMS and FiotX at the same time; BMS habits stay intact.
Command feedback

How do we verify a command took effect?

We show clearly where the state on screen comes from.

  • VRF bus: the setpoint and state the indoor unit applied are read back from the bus; the result is verified.
  • Infrared control: a split AC doesn't acknowledge commands. The screen shows "command sent"; room temperature is the indirect indicator.
  • Unknown values: if a brand doesn't expose a value, it shows as empty — never as zero or "normal".
FiotX setpoint 24 °C Gateway VRF bus Indoor unit applies → command ⇠ state read back VRF · setpoint 24 °C · unit applied ✓ IR · setpoint 24 °C · command sent
Pilot approach

Pilot approach

01 · SURVEY

Equipment & operating pattern

Brand, series, unit count, working hours and existing controllers/BMS. Which points will be read and managed is agreed in writing.

02 · PILOT

One floor or 5–10 units

The current state is recorded first, then schedules and setpoint limits go live. Duration depends on the site; 4–6 weeks is a typical start.

03 · REVIEW

Results against criteria

Data coverage, after-hours running time, comfort change, applied actions and, where a meter exists, condition-adjusted consumption.

Let's define the pilot scope together.

Share your equipment list and working pattern; we'll propose a pilot with written criteria.